Description
Built on the proven architecture of our flagship XD-502G2 platform, the XC-5 Digital Isokinetic Source Sampling Console delivers reliable, digital precision in a streamlined, cost-effective package. Engineered as a no-frills, entry-level solution, the XC-5 removes auxiliary components to cut down on weight and lower the barrier to entry without compromising measurement integrity. It serves as both the spiritual successor to the trusted XC-53 console, and a seamless, direct drop-in replacement for the XC-523 and XC-572 series consoles, offering an immediately intuitive workflow that feels familiar to all stack testers. With the XC-5 dropping the internal sample pump, you can continue to use your supply of portable, external pumps for ease of maintenance and utilization of existing inventory.
Behind the faceplate, the XC-5 pairs workhorse dependability with high-precision instrumentation. It features factory-calibrated electronic pressure transducers, an integrated digital vacuum sensor, an onboard barometric pressure sensor, and fully isolated thermocouple channels for readings. By combining the rugged familiarity of traditional Apex Instruments consoles with modern digital accuracy and reduced carrying weight, the XC-5 provides precision at a price point and form factor tailored for everyday field demands. A 32-bit microcontroller converts the sensor inputs and displays the totalized sample volume, temperatures, and pressures into configured units of measure. The transflective LCD display is sunlight-readable and backlit so it can be seen in the dark. Two advanced, self-tuning 1/32 DIN temperature controllers with individual solid-state relays are used for controlling heaters, e.g. probe and filter heaters. The digital LCD screen displays the dry gas meter volume, elapsed time, the dry gas meter differential orifice pressure (ΔH), stack velocity differential pressure (ΔP), and all 8 thermocouples. Coarse and fine valves are used to control the sample flow rate and to adjust the vacuum during leak checks. A 1/2″ sample inlet quick connect provides a convenient connection for the sample vacuum line. An easy-to-use 6-button keypad is used to reset the gas volume and elapsed time at the start of each sample period, along with other functions.
As with our other isokinetic source sampling consoles, the XC-5 can be used for all isokinetic testing methods, including US EPA Methods 2, 4, 5, 23, 26A, 29, 201A, 202, OTM-45, OTM-55, CTM-027, ASTM D6784-02 Ontario Hydro, and Solid Waste 846 Method 0010.
If you are looking for a data-logging console, check out our XD-502G2, or if you are looking for a fully-automated console, check out our XC-5000.
Looking to add a new pump to your XC-5? Check out our 0523 rotary vane or Ei-838 dual-diaphragm sample pumps.
Features
- Quick-swappable pressure transducers and vacuum sensor
- K-Factor input and automated target ΔH calculation
- 8-channel thermocouple sensor board for display of all 8 channels simultaneously
- Easy-to-use display, indoor or outdoor readable
- Rugged, lightweight case with 3 heavy-duty stainless-steel handles
- [OPTIONAL] internal Orsat pump with rotameter
Specifications
- Display: 4×20 character backlit transflective liquid crystal display, membrane switch for navigation of menu and sampling operations
- Dry Gas Meter: Model SK25EX, with 100 CPR quadrature encoder, 0.7L/rev., 1.45 ft3 (41 Lpm) max
- External Sample Pump: Not included, 3/8″ stainess-steel quick-connects with male/female connections
- Flow Indicator: Precision-machined, stainless-steel, venturi-style orifice tube affixed to dry gas meter outlet, electronic transducer differential pressure measurement
- Temperature Measurement: 8-channel individually isolated type-K thermocouple sensor board, -328 °F (-200 °C) to 2502 °F (1372 °C) range
- Probe & Oven Temperature Control: Fuji, compact, 1/32 DIN auto-tuning temperature controllers, individual 25-amp solid-state relays, type-K jacks for inputs, independent power switches
- Digital Pressure Transducers: User replaceable, factory calibrated, temperature compensated
- Pitot ΔP: ±1.0” H2O (25 mm) and ±10.0” H2O (250 mm) ranges, bi-directional, 0.01” H2O (0.1 mm) resolution
- ΔP automatically selects appropriate transducer range for current flow conditions
- Orifice ΔH: 6.5” (165 mm) range, 0.01” H2O (0.1 mm) resolution
- Pitot ΔP: ±1.0” H2O (25 mm) and ±10.0” H2O (250 mm) ranges, bi-directional, 0.01” H2O (0.1 mm) resolution
- Vacuum Sensor: User replaceable, electronic, digital scale, 0 to 30” Hg (0 to 760 mmHg), zero and span settings
- Barometric Pressure Sensor: Electronic, digital scale, temperature-compensated, 8.86 to 32.48″ Hg (225 to 825 mmHg)
- Umbilical Connections:
- Electrical: 5 pin conductor circular connector with ground (alternative styles available)
- Sample Inlet: 1/2” stainless steel instrumental quick-connect (alternative sizes available)
- Pitot Connections: 1/4” stainless steel instrumental quick-connects (alternative sizes available)
- Thermocouples: AUX, AUX2 or DGM In (Internal), DGM Out (Internal), Stack, Probe, Oven, Filter, and Exit
- External Pump: 3/8″ stainess-steel quick-connects with male/female connections (alternative sizes available)
- Power: Supply 120 VAC at 60 Hz 15 amps maximum or 240 VAC at 50 Hz 10 amps maximum, IEC C-14 inlet
- Dimensions: H17” x W17” x D12” (43 cm x 43 cm x 30.5 cm)
- Weight: 31 lbs (18 kg) base configuration